IUP & Ectopic Pregnancy Transvaginal Ultrasound Training Model - Medical Simulation for OB/GYN Education & Clinical Practice
$5990.73 $10892.24-45%
Free shipping on all orders over $50
7-15 days international
15 people viewing this product right now!
30-day free returns
Secure checkout
87729236
Guranteed safe checkout
DESCRIPTION
Combination IUP Ectopic Pregnancy Transvaginal Ultrasound Training Model
Blue Phantom’s combination Intrauterine Pregnancy (IUP) and Ectopic Pregnancy Transvaginal ultrasound training modeloffers the excellent imaging characteristics found in our Intrauterine Pregnancy Transvaginal model as well as EctopicPregnancy Transvaginal model, all in one life-like ultrasound training model. Manufactured using Blue Phantom’s patentedsimulated human tissue, this extremely realistic combination transvaginal medical training model offers the opportunityfor clinicians to develop and practice the psychomotor and imaging skills necessary to perform first trimestertransvaginal ultrasound exams. With your ultrasound system and Blue Phantom’s IUP and Ectopic Pregnancy Transvaginalphantom, it is possible for users of all levels to learn to scan, identify normal internal pelvic structures andpathology in the gravid first trimester patient using ultrasound sonography. Our combination pelvic model allows you theflexibility to learn where and when you want, without the risk, inconvenience, or expense of using human models.
Contains both an intrauterine pregnancy as well as an ectopic pregnancy
Blue Phantom expends tremendous effort to match the imaging characteristics of real human tissue, offering you the procedural realism required to train under optimal conditions. Our combination endovaginal model is anatomically correct both externally and internally, allowing users to practice all of the elements necessary to gain proficiency in performing transvaginal ultrasound sonography on gravid patients in their first trimester of pregnancy. Mimicking both the feel and imaging characteristics of an actual endovaginal exam, the IUP and Ectopic combination training model is a great tool to train users to perform endovaginal ultrasound procedures on a patient in her first trimester of pregnancy with either ectopic or intrauterine pregnancy.
This combination transvaginal ultrasound training model includes all of the anatomical components found in ourindividual Ectopic Pregnancy and Intrauterine Pregnancy ultrasound training models and includes anatomically correctstructures of the gravid female pelvis during the first trimester including: anatomically accurate external anatomy, theendovaginal canal, bladder with bladder wall, cervix, uterus with intrauterine pregnancy, extrauterine pregnancy,endometrium, left and right ovaries, ovarian follicles, corpus luteum cyst, broad ligaments, maternal bowel and colon,free fluid in cul-de-sac, and accessory structures all positioned within a realistic female lower torso. Bothintrauterine and ectopic pregnancies are of a 7 week gestational age fetus complete with amnion and placenta. Theanatomical realism allows users to develop the skills necessary to utilize ultrasound in your clinical environment forthe evaluation of 1st trimester pregnancies using transvaginal (endovaginal) ultrasound. Users can develop and practiceusing ultrasound system controls, transducer positioning and movement, as well as utilize obstetrical (Ob) ultrasoundcalculation packages to measure cysts, crown rump length (CRL), and the gestational sac.
Develop and practice the psychomotor and imaging skills necessary to perform first trimester transvaginal ultrasound exams
Blue Phantom’s durability offers you the most realistic training environment available anywhere at a lowcost of ownership. Our tissue technology accurately simulates the ultrasound imaging characteristics found in theobstetrical and gynecological human patient. This extremely realistic simulation mannequin performs well using anyultrasound system configured with the appropriate transducer (recommended ultrasound transducer: endovaginal ultrasoundprobe 5.0-12 MHz). Our IUP and Ectopic Pregnancy Transvaginal phantom is excellent for using 2-D, 3-D, and 4-Dultrasound imaging techniques.
This is not computer simulation. We know that the best simulation trainingscenarios are requisite on users experiencing the same procedural realism as performing the procedure on patients. Withthe IUP and Ectopic Pregnancy combination ultrasound phantom, you can train users to use your own ultrasound system andcontrols to gain proficiency in your realistic training environment. When you use your ultrasound system on ourintrauterine pregnancy and ectopic pregnancy transvaginal ultrasound training model, you experience the same quality youexpect from imaging patients in a clinical environment.
This medical training model is excellent forspecialties including Ob/Gyn, emergency medicine, fertility training programs, simulation centers, medical educationfacilities, and ultrasound manufacturers for ultrasound education on demonstration.
Specifications
Extremely realistic real-time ultrasound imaging model – use your own ultrasound system for transvaginal ultrasound training
1st trimester intrauterine and ectopic pregnancy endovaginal ultrasound training model excellent for training clinicians in the psychomotor and imaging skills associated with transvaginal ultrasound procedures
Extremely realistic external anatomy
Internal anatomy with sonographically accurate endovaginal canal, bladder with bladder wall, cervix, uterus with intrauterine pregnancy, extrauterine pregnancy, endometrium, left and right ovaries, ovarian follicles, corpus luteum cyst, broad ligaments, maternal bowel and colon, free fluid in cul-de-sac, and accessory structures
Both intrauterine and ectopic pregnancies are of a 7 week gestational age fetus/embryo complete with amniotic sac and placenta
Superb ultrasound imaging characteristics
Accurately mimics the feel and imaging characteristics of an actual endovaginal ultrasound exam
Easy to clean – though not routinely necessary
No replacement parts necessary
Tissues match the acoustic characteristics of real human tissue so when you use your ultrasound system on our training models, you experience the same quality you expect from imaging patients in a clinical environment
Performs well using any ultrasound imaging system
Practice using ultrasound system controls
Excellent for 3-D and 4-D ultrasound imaging and reconstruction
Excellent for validating clinical competency
Additional configurations available: normal and pathology phantoms
High quality
No special storage requirements
Includes privacy skirt and padded soft storage/ travel case
Patented technology
Size: Actual Weight – 22lbs (10kg)
Shipping Weight – 20lbs (14kg)
Product Dimensions – 18” x 18” x 12” (45cm x 45cm x 30cm) (L x W x H)
What's in the Box
Combination Intrauterine and Ectopic Pregnancy Transvaginal Ultrasound Model
Soft Storage Case with Foam Block
Privacy Skirt
Made in USA
GTSimulators by Global Technologies CAE Healthcare Authorized Distributor.